English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

How electrochemical sensors measure up to reference-grade nitrogen dioxide monitors across temporal scales

Authors
/persons/resource/431

Schmitz,  Sean
Research Institute for Sustainability – Helmholtz Centre Potsdam (RIFS);

/persons/resource/1515

Caseiro,  Alexandre
Research Institute for Sustainability – Helmholtz Centre Potsdam (RIFS);

/persons/resource/139

von Schneidemesser,  Erika
Research Institute for Sustainability – Helmholtz Centre Potsdam (RIFS);

External Ressource
No external resources are shared
Fulltext (public)

6004348.pdf
(Publisher version), 10MB

Supplementary Material (public)
There is no public supplementary material available
Citation

Schmitz, S., Caseiro, A., von Schneidemesser, E. (2025): How electrochemical sensors measure up to reference-grade nitrogen dioxide monitors across temporal scales. - Science of the total environment, 980, 179476.
https://doi.org/10.1016/j.scitotenv.2025.179476


Cite as: https://publications.rifs-potsdam.de/pubman/item/item_6004348
Abstract
Air pollution remains a critical global health challenge, with nitrogen dioxide (NO₂) playing a significant role in adverse health outcomes. Low-cost sensors (LCS) offer promising opportunities for accessible and high-resolution air quality monitoring but face scrutiny over their accuracy and reliability. This study evaluates the performance of electrochemical LCS for NO₂ measurement in comparison to high-precision reference instruments—cavity attenuated phase shift (CAPS) and chemiluminescence NO₂ monitors—at eleven temporal resolutions (between 10-s and 6-h). Using three EarthSense Zephyrs containing electrochemical sensors, data were collected over six months at an urban-traffic air quality monitoring site in Berlin. Sensor performance was assessed based on statistical metrics, including R2, relative error, and mean bias error (MBE). Results revealed that LCS exhibit good agreement with reference instruments at coarse time resolutions (≥1-h averages, R2 > 0.8), but accuracy diminishes significantly at higher resolutions (<1-min, R2 < 0.5). Overall, LCS perform better when trained against CAPS monitors than against chemiluminescence monitors. This performance is largely influenced by chemistry and emissions, with poorer performance during the daytime than at night, a pattern which is exacerbated at high time resolutions. CAPS-calibrated predictive models outperform those calibrated against chemiluminescence monitors in capturing short-term concentration peaks. These findings suggest that while LCS are suitable for coarse-resolution measurements of NO2, their limitations in high temporal resolution dynamic environments pose significant challenges for their use in exposure studies and mobile measurements. Recommendations for improved LCS deployment include careful calibration, strategic experimental design, and focused application on lower time-resolution monitoring.